This unit MUST be plugged into a dedicated electrical circuit with a breaker to insure consistent current.
SOREDEX DIGORA OPTIME MANUAL MANUAL
which I'm thinking has got to be a prime suspect.Delivery – Continental US only, Training – Basic Training, Warranty – 1-year parts, 90-day labor DIGORA ® Optime DXR-60 Field Service Manual 209124 rev 3 (2013-10) 4 (63) INTRODUCTION. I did find a few service manuals, etc for it online (below) and I notice it has a drive belt of sorts. Is this perhaps a common mechanical fault? Soredex DIGORA Optime Intraoral imaging: SciCan STATIM 2000 G4 Sterilizer Introducing the new, 4th generation STATIM by SciCan.-Fast USB port for manual. Has anyone got any experience of these things?.
SOREDEX DIGORA OPTIME MANUAL SOFTWARE
While my feeling is that its a mechanical fault, they tell me that the software has to be open in order to load a slide, which makes the supplier's reasoning plausible I guess. My customer feels they're being "fobbed off" by the supplier and have asked me to take a look at it. The five receptors a Kodak paper pack film (Eastman Kodak Company, Rochester, NY), a DIGORA Optime phosphor plate (Soredex, Tuusula, Finland), and SuniRay. They spoke to the supplier who are now saying the fault is with the connection to the computer. They tell me it worked once after that but now it's back to the same fault. DIGORA Optime DXR-60 Field Service Manual 209124 rev 3 (2013-10) 20 (63) 1-14 ERRORK100DOORCLOSEDOPTO Plate carrier is at home position and light in the door closed opto is blocked (Door should be open) 1-15 ERRORK100ETHPHY 1-16 ERRORK100ADC In cases 1-11,12,13 it is recommended first to check that there are no dust or other particles that blocks the light in the door optos. Today they phoned me again: Apparently, the supplier sent out a tech, who moved it around, wiggled a few wires and declared it 'fixed'. Board where supply voltages to internal circuits are made Other boards are powered from K100. Powering of the boards: INPUT voltage 24VDC from External Power Supply is connected to K100 Main. I suggested that they contact their supplier and ask them to take a look at it. DIGORA Optime DXR-60 Field Service Manual 209124 rev 3 (2013-10) 10 (63) Covers and UI-Frame assembly removed. They told me that the loading mechanism moves in and out repeatedly but won't accept/recognise the x-ray slides. I'm yet to see the problem myself, but from their description, it sounded to me like there may be a mechanical fault with the device. It connects to the network and they operate it via software called 'Digora for Windows'.Ī week or so ago they phoned me because they had a problem loading the x-ray images into it. I maintain their computers and network but, other than connecting this scanner to the network, I usually have very little to do with it. It belongs to a dental practice customer of mine.
SOREDEX DIGORA OPTIME MANUAL HOW TO
From the imaging application software you are using select unit Setup/Scanner page (for more instruction on how to access setup page review application software manual).

just wondering if anyone here has any experience with these things: The DIGORA ® Optime setup options allow you to configure the DIGORA ® Optime to the user’s clinical preferences.